Using more than one Sensor at a time

28/04/2014

 

Question:

ZF Automotive in Nottingham have bought 3 CAPTURE Systems, each CAPTURE Display Unit has 2 or 3 Sensors in use, so the operators are having to keep reconnecting the cable to the Sensor in use at the time.            
                         
This is not an ideal solution, what can be done?


Answer:

Gedore Torque are designing a 4 Way Switching Unit which can have up to 4 Sensors all plugged in at the same time, so now all the operator has to do is just select the switch to the Sensor he intends to use.

Website design, build and SEO by Red Ant Solutions